The LONGER Nano Duo features a built-in camera system that helps users preview the engraving area and position designs more accurately before starting a project.

To use the camera function in LightBurn, the camera needs to be calibrated and aligned first. Proper calibration ensures that the design position in LightBurn matches the actual engraving position on the material.

This guide explains how to complete the Nano Duo camera calibration and alignment process in LightBurn.

1. Focus the Nano Duo Before Calibration

Before starting camera calibration, make sure the Nano Duo is correctly focused.

Incorrect focus may cause a difference between the design size shown in LightBurn and the actual engraved result. The final engraving may appear larger or smaller than expected. Complete the focusing process first, then continue with camera calibration.

2. Camera Calibration

Open LightBurn and select "Calibrate Camera Lens" in laser tools.

Open LightBurn and select Calibrate Camera Lens in laser tools

Selecting "USB Camera" and "Standard Lens" in the interface, click "Next".

USB Camera Standard Lens Next

Place the calibration card in the camera view as shown, turn off "Honeycomb check enable", clik "Capture" button, and when "Next" lights up, proceed to the next step. Repeat the same operation multiple times.

capture

Note: A 90-degree rotation of the image is normal and does not affect camera calibration. Position the calibration card according to the diagram; the orientation of the device does not matter.

Until the interface as shown and click "Align Camera", and the lens calibration is completed.

align camera

3. Camera alignment

At the end of section 2, click "Align Camera" ,select "USB Camera", and click "Next".

usb camera

In addition, you can also enter through "Calibrate Camera Alignment" in lasertools.

calibrate camera alignment

Place the wooden board, adjust the focus, set the engraving parameters, click "Frame" to confirm the engraving range is within the wooden board, and then click Engraving, and click "Next" after engraving.

Note: When carving thick materials like wood, refocusing is required.

refocusing

Click the "Capture Image" button to capture. When the image is clear in the camera view, click "Next". If it is not clear, recapture it or return to the previous step and engraving it again.

capture image

Pan and zoom to find the four corner marks, and double-click in the center of each one as precisely as you can. It is important that you mark the corners in their numbered order(1, 2, 3, 4).

marked all four corners

When you have marked all four corners, click "Next" to continue.